1 = {{id name="HSiemens"/}}**Siemens** =
2
3 == {{id name="HS7-200SmartA0Ethernet"/}}**S7-200 Smart Ethernet** ==
4
5 Supported Series: Siemens S7-200 SMART Series Ethernet Module.
6
7 Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
8
9 **HMI Setting**
10
11 |**Items**|**Settings**|**Note**
12 |Protocol|Simens S7-200 Smart Ethernet|
13 |Connection|Ethernet|
14 |Port No.|102|
15 |PLC station No.|2|
16
17 **Address List**
18
19 |**Type**|**Device register**|**Format**|**Range**|**Note**
20 |(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7|
21 |Q|Q ddddd.o|0.0~~99999.7|
22 |V|VWbit ddddd.o|0.0~~99999.7|HMI register:VWbit
23 |V|V ddddd.o|0.0~~99999.7|HMI register:V
24 |M|M ddddd.o|0.0~~99999.7|
25 |SM|ddddd.o|0.0~~99999.7|
26 |S|ddddd.o|0.0~~99999.7|Read only
27 |T|ddddd|0~~99999|Timer state, read only
28 |C|ddddd|0~~99999|Counter state, read only
29 |(% colspan="1" rowspan="18" %)Word|(% colspan="1" rowspan="2" %)I|IW ddddd|0~~99999|HMI register:IW
30 |IB ddddd|0~~99999|HMI register:IB
31 |(% colspan="1" rowspan="2" %)Q|QW ddddd|0~~99999|HMI register:QW
32 |QB ddddd|0~~99999|HMI register:QB
33 |(% colspan="1" rowspan="2" %)AI|AIW ddddd|0~~99999|HMI register:AIW
34 |AIB ddddd|0~~99999|HMI register:AIB
35 |(% colspan="1" rowspan="2" %)AQ|AQW ddddd|0~~99999|HMI register:AQW
36 |AQB ddddd|0~~99999|HMI register:AQB
37 |(% colspan="1" rowspan="3" %)V|VW ddddd|0~~99998|(((
38 HMI register:VW
39
40 VW0=VB (0~~1)
41
42 VW2=VB (2~~3)
43
44 Address value is a multiple of 2
45 )))
46 |VD ddddd|0~~99996|(((
47 HMI register:VD
48
49 VD0=VB (0~~3)
50
51 VD2=VB (4~~7)
52
53 Address value is a multiple of 4
54 )))
55 |VB ddddd|0~~99998|HMI register:VB
56 |(% colspan="1" rowspan="3" %)M|MW ddddd|0~~30|(((
57 HMI register:MW
58
59 MW0=MB(0~~1)
60
61 MW2=MB(2~~3)
62
63 Address value is a multiple of 2
64 )))
65 |MD ddddd|0~~99999|(((
66 (((
67 HMI register:MD
68
69 MD0=MB(0~~3)
70
71 MD4=MB(4~~7)
72
73 Address value is a multiple of 4
74 )))
75
76 (((
77
78 )))
79 )))
80 |MD dd|0~~31|HMI register:MB
81 |T|TW ddddd|0~~99999|(((
82 HMI register:MW
83
84 Value of timer
85 )))
86 |C|CW ddddd|0~~99999|(((
87 HMI register:CW
88
89 Value of counter
90 )))
91 |(% colspan="1" rowspan="2" %)S|SW ddddd|0~~99999|HMI register:SW
92 |SB ddddd|0~~99999|HMI register:SB
93
94 **Communication Settings**
95
96 Set PLC IP in [Device IP] settings;
97
98 {{id name="I12.PLCProtocol_html_70b0c4c2ee21b10d.png"/}}[[image:2.1.png||alt="12.PLC Protocol_html_70b0c4c2ee21b10d.png"]]
99
100 * PLC IP Address: PLC IP
101 * PLC pot No.: 102(fixed)
102 * Network:TCP_Client_2N(fixed)
103
104 {{id name="I12.PLCProtocol_html_5891afd92901b7ad.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_2043e24eb003e3a5.png||alt="12.PLC Protocol_html_5891afd92901b7ad.png" height="276" width="347"]]
105
106 * Wait timeout: depend on actual network situation (more than 1500 ms)
107
108 **PLC Setting:**
109
110 ①Open STEP 7-MicroWIN SMART, create a new PLC project or open the project that has been created.
111 Create new project:Double click[CPU SR20]→[System Block]→[Module] CPU SR20(AC/DC/Relay)→[OK].
112
113 (% style="text-align:center" %)
114 [[image:1.2.png]]
115
116 ②PLC Default Parameters: Double click[CPU SR20]→[System Block]→[Ethernet Port]→[IP Address]192.168.39.21[Subnet Mask]255.255.255.0[Default Gateway]192.168.39.1→[OK]
117
118 (% style="text-align:center" %)
119 [[image:1.3.png]]
120
121 **Cable Wiring**
122
123 {{id name="I12.PLCProtocol_html_2297240b57346b2a.png-4"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
124
125 == {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet** ==
126
127 Supported Series: Siemens S7-300 series PLC
128
129 **HMI Setting**
130
131 |**Items**|**Settings**|**Note**
132 |Protocol|Simens S7-300 Ethernet|
133 |Connection|Ethernet|
134 |Port No.|102|
135 |PLC station No.|2|Need to be same as the PLC setting
136
137 **Address List**
138
139 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
140 |(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
141 |Q|Q|Q ddddd.o|0.0~~99999.7|
142 |M|M|M ddddd.o|0.0~~99999.7|
143 |DB0.DB~~DB9999.DB|DBxDBD|DBxDB nnnndddd.o|0.0~~99999999.7|(((
144 nnnn: block number;
145
146 dddd: address;
147 )))
148 |(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
149 |Q|QW|QW ddddd|0~~99999|
150 |(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
151 |MW|MW ddddd|0~~99999|(((
152 MW0=MB(0~~1)
153
154 MW2=MB(2~~3)
155
156 Address value is a multiple of 2
157 )))
158 |MD|MD ddddd|0~~99999|(((
159 MD0=MB(0~~3)
160
161 MD4=MB(4~~7)
162
163 Address value is a multiple of 4
164 )))
165 |(% rowspan="3" %)DB0.DB~~DB9999.DB|DBxDBB|DBxDBB nnnndddd|0~~99999999|(% rowspan="3" %)(((
166 nnnn: block number;
167
168 dddd: address
169 )))
170 |DBxDBW|DBxDBW nnnndddd|0~~99999999
171 |DBxDBD|DBxDBD nnnndddd|0~~99999999
172
173 **Communication Settings**
174
175 Enable HMI Ethernet in [Project Settings];
176
177 {{id name="I12.PLCProtocol_html_43b671f18153910d.png-7"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
178
179 Set PLC IP in [Device IP] settings;
180
181 {{id name="I12.PLCProtocol_html_910b1a0aa9e2201c.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c63825de4f904ef1.png||alt="12.PLC Protocol_html_910b1a0aa9e2201c.png" height="188" width="554"]]
182
183 * PLC IP Address: PLC IP
184 * PLC pot No.: 102(fixed)
185 * Network:TCP_Client_2N(fixed)
186
187 {{id name="I12.PLCProtocol_html_5891afd92901b7ad.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_2043e24eb003e3a5.png||alt="12.PLC Protocol_html_5891afd92901b7ad.png" height="276" width="347"]]
188
189 * Wait timeout: depend on actual network situation (more than 1500 ms)
190
191 **Cable Wiring**
192
193 {{id name="I12.PLCProtocol_html_2297240b57346b2a.png-5"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
194
195 == {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet** ==
196
197 Supported Series: Siemens S7-1200
198
199 **HMI Setting**
200
201 |**Items**|**Settings**|**Note**
202 |Protocol|Siemens S7-1200|
203 |Connection|Ethernet|
204 |Port No.|102|
205 |PLC station No.|2|
206
207 **Address List**
208
209 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
210 |(% rowspan="4" %)Bit|I|I|M d.o|(((
211 d:0~-~-9999
212
213 o:0-7
214 )))|
215 |Q|Q|Q d.o|(((
216 d:0~-~-9999
217
218 o:0-7
219 )))|
220 |M|M|M d.o|(((
221 d:0~-~-9999
222
223 o:0-7
224 )))|
225 |DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
226 nn:0-9999,
227
228 dddd:0-9999,
229
230 o:0-7
231 )))|(((
232 nn:DB No.
233
234 dddd:address value
235
236 o: digit address
237 )))
238 |(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
239 |M|MW|MW d|d:0-99999|(((
240 MW0=MB(0~~1)
241
242 MW2=MB(2~~3)
243
244 Address value is a multiple of 2
245 )))
246 |M|MD|MD d|d:0-99999|(((
247 MD0=MB(0~~3)
248
249 MD4=MB(4~~7)
250
251 Address value is a multiple of 4
252 )))
253 |I|IW|IW d|d:0-99999|
254 |Q|QW|QW d|d:0-99999|
255 |DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
256 nn:0-9999
257
258 dddd:0-9999
259 )))|(((
260 nn:DB No.
261
262 dddd:address value
263 )))
264 |DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
265 nn:0-9999
266
267 dddd:0-9999
268 )))|(((
269 nn:DB No.
270
271 dddd:address value
272
273 Address value is a multiple of 2
274 )))
275 |DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
276 nn:0-9999
277
278 dddd:0-9999
279 )))|(((
280 nn:DB No.
281
282 dddd:address value
283
284 Address value is a multiple of 4
285 )))
286
287 **Communication Settings**
288
289 Enable HMI Ethernet in [Project Settings];
290
291 {{id name="I12.PLCProtocol_html_43b671f18153910d.png-8"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
292
293 Set PLC IP in [Device IP] settings;
294
295 {{id name="I12.PLCProtocol_html_f7b3eb9abda33833.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ded8f04f5bfd39be.png||alt="12.PLC Protocol_html_f7b3eb9abda33833.png" height="190" width="554"]]
296
297 **✎Note:**
298
299 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
300 * HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
301 * S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address.
302 * HMI operation character length needs to be set to 2 times the length of the Siemens character for proper display.
303
304 **PLC Settings**
305
306 Add BD
307
308 * Please uncheck [Symbolic access only] option;
309
310 {{id name="I12.PLCProtocol_html_643144c591994418.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png||alt="12.PLC Protocol_html_643144c591994418.png" height="546" width="550"]]
311
312 Address settings, using BD2 as example.
313
314 * DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
315 * 2 represent DB block number
316 * xxxx represent address
317
318 **Such as:**
319
320 * DBxDBB20000 = DB2.DBB0
321 * DBxDBW20004 = DB2.DBW4
322
323 {{id name="I12.PLCProtocol_html_87ceaea84d552e62.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png||alt="12.PLC Protocol_html_87ceaea84d552e62.png" height="245" width="537"]]
324
325 **How to connect with S7-1200 Firmware V4.0**
326
327 PLC configuration
328
329 * Double click [device configuration] in Siemens via software
330 * Double click [protection] to enter protection configuration screen
331
332 {{id name="I12.PLCProtocol_html_9779940d38da8e07.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png||alt="12.PLC Protocol_html_9779940d38da8e07.png" height="426" width="341"]]
333
334 * Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
335
336 {{id name="I12.PLCProtocol_html_d2c667b02f9720b1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png||alt="12.PLC Protocol_html_d2c667b02f9720b1.png" height="296" width="554"]]
337
338 DB settings
339
340 * Right click [DB], select [properties]
341 * Uncheck [optimized block access]
342
343 **Cable Wiring**
344
345 {{id name="I12.PLCProtocol_html_2297240b57346b2a.png-6"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
346
347 == {{id name="HS7-XXXEthernet"/}}**S7-XXX Ethernet** ==
348
349 Supported Series: Siemens S7-400, S7-1200 and S7-1500
350
351 **HMI Setting**
352
353 |=**Items**|=**Settings**|=**Note**
354 |Protocol|Siemens S7-XXX|
355 |Connection|Ethernet|
356 |Port No.|102|
357 |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
358 |HMI No.|Rack (Default as 0)|
359
360 Slot from TIA Portal is equal to Device No. of PIStudio
361
362 Rack from TIA Portal is equal to HMI No. of PIStudio
363
364 {{id name="IS7-XXXCommunicationSettings.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d78bc267e5fc6394.png||alt="S7-XXXCommunication Settings.png" height="503" width="798"]]
365
366 {{id name="IS7-XXXCommunicationSettingsPIStudio.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_561c9c5b1c99916b.png||alt="S7-XXXCommunication SettingsPI.png" height="706" width="908"]]
367
368 **Address List**
369
370 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
371 |(% rowspan="4" %)Bit|I|I|M d.o|(((
372 d:0~-~-9999
373
374 o:0-7
375 )))|
376 |Q|Q|Q d.o|(((
377 d:0~-~-9999
378
379 o:0-7
380 )))|
381 |M|M|M d.o|(((
382 d:0~-~-9999
383
384 o:0-7
385 )))|
386 |DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
387 nn:0-9999,
388
389 dddd:0-9999,
390
391 o:0-7
392 )))|(((
393 nn:DB No.
394
395 dddd:address value
396
397 o: digit address
398 )))
399 |(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
400 |M|MW|MW d|d:0-99999|(((
401 MW0=MB(0~~1)
402
403 MW2=MB(2~~3)
404
405 Address value is a multiple of 2
406 )))
407 |M|MD|MD d|d:0-99999|(((
408 MD0=MB(0~~3)
409
410 MD4=MB(4~~7)
411
412 Address value is a multiple of 4
413 )))
414 |I|IW|IW d|d:0-99999|
415 |Q|QW|QW d|d:0-99999|
416 |DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
417 nn:0-9999
418
419 dddd:0-9999
420 )))|(((
421 nn:DB No.
422
423 dddd:address value
424 )))
425 |DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
426 nn:0-9999
427
428 dddd:0-9999
429 )))|(((
430 nn:DB No.
431
432 dddd:address value
433
434 Address value is a multiple of 2
435 )))
436 |DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
437 nn:0-9999
438
439 dddd:0-9999
440 )))|(((
441 nn:DB No.
442
443 dddd:address value
444
445 Address value is a multiple of 4
446 )))
447
448 **Communication Settings**
449
450 Enable HMI Ethernet in [Project Settings];
451
452 {{id name="I12.PLCProtocol_html_43b671f18153910d.png-9"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
453
454 Set PLC IP in [Device IP] settings;
455
456 {{id name="I12.PLCProtocol_html_f7b3eb9abda33833.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ded8f04f5bfd39be.png||alt="12.PLC Protocol_html_f7b3eb9abda33833.png" height="190" width="554"]]
457
458 **✎Note:**
459
460 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
461 * HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
462
463 **Cable Wiring**
464
465 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-5"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
466
467 == {{id name="cke_bm_25456S"/}}{{id name="HLOGOEthernet"/}}** LOGO Ethernet** ==
468
469 Supported Series: Siemens Logo 0BA0, 0BA1 series
470
471 **HMI Settings**
472
473 |**Items**|**Settings**|**Note**
474 |Protocol|Siemens LOGO|
475 |Connection|Ethernet|
476 |Port No.|102|
477 |PLC station No.|2|
478
479 **Address List**
480
481 |**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
482 |1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
483 |2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
484 |3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
485 |4|VW|Word|0-1468|DB1.DBX0.0|0x000000
486 |5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
487 |6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
488 |7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
489 |8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
490 |9|AI|Word|1-16|DB1.DBX1032.0|0x002040
491 |10|I|Bit|1-64|DB1.DBX1024.0|0x002000
492 |11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
493 |12|M|Bit|1-112|DB1.DBX1104.0|0x002280
494 |13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
495 |14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
496 |15|V|Bit|0-14697|DB1.DBX0.0|0x000000
497
498 **PLC Settings in LOGO Software:**
499
500 Click [Tools]~-~-[Ethernet Connections],shown as below.
501
502 {{id name="I12.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]
503
504 Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
505
506 {{id name="Iimage-20221228142937-4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]
507
508 **TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
509
510 {{id name="Iimage-20221228143047-5.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]
511
512 **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
513
514 {{id name="Iimage-20221228143246-6.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]
515
516 **HMI Communication Settings**
517
518 Set PLC IP in [Device IP] settings;
519
520 {{id name="Iimage-20221228143614-7.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_58cea5198cb7c78a.png||alt="image-20221228143614-7.png" height="706" width="909"]]
521
522 Enable HMI Ethernet in [Project Settings];
523
524 {{id name="Iimage-20221228144229-9.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7904cd9b484f6634.png||alt="image-20221228144229-9.png" height="451" width="793"]]
525
526 TSAP setting
527
528 * Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
529 * HSW10118/HSW1200 = local TSAP of HMI, this is remote TSAP of PLC.
530 * HSW10119/HSW1201 = Remote TSAP of HMI, this is local TSAP of PLC.
531 * PI, PI+, i series (1.0 system): use HSW10118, HSW10119.
532 ie, ig series: use HSW1200, HSW1201.
533 HMI V2.0: use HSW1200, HSW1201.
534
535 **✎Note:**
536
537 * The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118/HSW1200 should be set to 0x2000, that is, HSW10118/HSW1200=8192.
538 * HSW10119/HSW1201 is set up as shown.
539 * {{id name="Iimage-20221228144800-11.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c518682b5f97ac1b.png||alt="image-20221228144800-11.png" height="144" width="538"]]
540 * {{id name="Iimage-20221228144708-10.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_885bd6754ccb5593.png||alt="image-20221228144708-10.png" height="127" width="537"]]
541
542 * AI word address and Ibit address are read-only and cannot be written on HMI.
543 * VW address should be even number address, such as VW0, VW2, VW4..., because in the address rule of Siemens PLC, the value of odd number address is equal to the value of previous even number address. For example VW1 = VW0.
544 * VD address should be multiple of 4, because it occupies two VW addresses, such as VD0, VD4, VD8...
545 * Written value of RTC cannot exceed 255.
546
547 **Cable Wiring**
548
549 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-6"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
550
551 == {{id name="HS7-30028WithPCAdapter29"/}}**S7-300(With PC Adapter)** ==
552
553 **HMI Setting:**
554
555 |=**Parameters**|=**Recommended**|=**Options**|=**Notes**
556 |=**PLC type**|(% colspan="2" %)SIEMENS S7-300 (with PC Adapter)|
557 |=**PLC I/F**|RS232| |
558 |=**Baud rate**|19200|9600,19200|
559 |=**Data bits**|8| |
560 |=**Parity**|Odd| |
561 |=**Stop bits**|1| |
562 |=**PLC sta. no.**|2| |Must be same as the PLC setting.
563
564 **Device Address**
565
566 |=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
567 |=Bit|I|DDDDo|0 ~~ 40957|Input (I)
568 |=Bit|Q|DDDDo|0 ~~ 40957|Output (O)
569 |=Bit|M|DDDDo|0 ~~ 40957|Bit Memory
570 |=Word|DB1 to DB99|DDDDDo|0 ~~ 655327|
571 |=Word|IW|DDDD|0 ~~ 4095|Input (I)
572 |=Word|QW|DDDD|0 ~~ 4095|Output (O)
573 |=Word|MW|DDDD|0 ~~ 4095|Bit Memory
574 |=Double word|MD|DDDD|0 ~~ 4094|
575 |=Double word|DBDn|FFFFFDDDD|0 ~~ 655359999|Data Register Double Word (must be even)
576 |=Byte|MB|DDDD|0 ~~ 4095|Bit Memory Byte
577
578 **Cable Wiring**
579
580 {{id name="Iimage-20221010102051-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_77dc63b5c3645636.png||alt="image-20221010102051-1.png" height="239" width="395"]]
581
582 == **S7-200 Smart Serial ** ==
583
584 Supported Series: Siemens S7-200 SMART Series.
585
586 Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
587
588 **HMI Setting**
589
590 |=**Parameters**|=**Recommended**|=**Notes**
591 |=**PLC type**|(% colspan="1" %)SIEMENS S7-200 CPU22x/Smart PPI new|
592 |=**PLC I/F**|RS485|
593 |=**Baud rate**|9600|
594 |=**Data bits**|8|
595 |=**Parity**|EVEN|
596 |=**Stop bits**|1|
597 |=**PLC sta. no.**|2|Must be same as the PLC setting.
598
599 **Address List**
600
601 (% style="width:1081px" %)
602 |=(% style="width: 114px;" %)**Type**|=(% style="width: 287px;" %)**Device registers**|=**HMI registers**|=**Format**|=**Range**|=(% style="width: 112px;" %)**Note**
603 |(% colspan="1" rowspan="9" style="width:114px" %)Bit|(% style="width:287px" %)I|I|I d|0~~99999|(% style="width:112px" %)
604 |(% style="width:287px" %)Q|Q|Q d|0~~99999|(% style="width:112px" %)
605 |(% style="width:287px" %)VWBit|VWBit|VWBit d|0~~99999|(% style="width:112px" %)
606 |(% style="width:287px" %)V|V|V d|0~~99999|(% style="width:112px" %)
607 |(% style="width:287px" %)M|M|M d|0~~99999|(% style="width:112px" %)
608 |(% style="width:287px" %)SM|SM|SM d|0~~99999|(% style="width:112px" %)
609 |(% style="width:287px" %)S|S|S d|0~~99999|(% style="width:112px" %)
610 |(% style="width:287px" %)T|T|T d|0~~99999|(% style="width:112px" %)
611 |(% style="width:287px" %)C|C|C d|0~~99999|(% style="width:112px" %)
612 |(% colspan="1" rowspan="10" style="width:114px" %)Word|(% style="width:287px" %)IW|IW|IW d|0~~99998|(% style="width:112px" %)
613 |(% style="width:287px" %)QW|QW|QW d|0~~99998|(% style="width:112px" %)
614 |(% style="width:287px" %)AIW|AIW|AIW d|0~~99998|(% style="width:112px" %)
615 |(% style="width:287px" %)AQW|AQW|AQW d|0~~99998|(% style="width:112px" %)
616 |(% style="width:287px" %)VW|VW|VW d|0~~99998|(% style="width:112px" %)
617 |(% style="width:287px" %)MW|MW|MW d|0~~30|(% style="width:112px" %)
618 |(% style="width:287px" %)SW|SW|SW d|0~~99998|(% style="width:112px" %)
619 |(% style="width:287px" %)SMW|SMW|SMW d|0~~99998|(% style="width:112px" %)
620 |(% style="width:287px" %)TW|TW|TW d|0~~99999|(% style="width:112px" %)
621 |(% style="width:287px" %)CW|CW|CW d|0~~99999|(% style="width:112px" %)
622
623 **Configure the communication protocol**
624
625 (% style="text-align:center" %)
626 [[image:2.3.png]]
627
628 (% style="text-align:center" %)
629 [[image:2.3.2.png]]
630
631 **PLC Settings(STEP 7-MicroWIN SMART)**
632
633 Open STEP 7-MicroWIN SMART, create a new PLC project or open the project that has been created.
634 Create new project:Double click[CPU SR20]→[System Block]→[Module] CPU SR20(AC/DC/Relay)→[OK].
635
636 (% style="text-align:center" %)
637 [[image:1.2.png]]
638
639 PLC Default Parameters: Double click[CPU SR20]→[System Block]→[RS485 Port]→[Address]2,[Baud Rate]9.6Kbps→[OK]
640
641 (% style="text-align:center" %)
642 [[image:1.3.png]]
643
644 **Cable Wiring**
645
646 (% style="text-align:center" %)
647 [[image:Cable Wiring.png||height="200" width="721"]]
648
649 Pin Definition Diagram
650
651 (% style="text-align:center" %)
652 [[image:Pin Definition Diagram.png||height="200" width="411"]]
653
654 == **S7-200(Ethernet with 243)** ==
655
656 Supported Series: Siemens S7-200(Ethernet with 243)
657
658 **HMI Setting**
659
660 (% style="width:1420px" %)
661 |=(% style="width: 431px;" %)**Items**|=(% style="width: 543px;" %)**Settings**|=(% style="width: 444px;" %)**Note**
662 |=(% style="width: 431px;" %)Protocol|(% style="width:543px" %)Siemens S7-200(Ethernet with 243)|(% style="width:444px" %)(((
663
664 )))
665 |=(% style="width: 431px;" %)Connection|(% style="width:543px" %)Ethernet|(% style="width:444px" %)
666 |=(% style="width: 431px;" %)Port No.|(% style="width:543px" %)102|(% style="width:444px" %)
667 |=(% style="width: 431px;" %)PLC station No.|(% style="width:543px" %)2|(% style="width:444px" %)
668
669 (% class="box infomessage" %)
670 (((
671 **✎**Note: IF the [SIEMENS S7-200(Ethernet With 243)] can not link.Please choose [SIEMENS S7-200 Smart (Ethernet)] to test again.
672 )))
673
674 **Address List**
675
676 (% style="width:1429px" %)
677 |=(% style="width: 252px;" %)**Bit/Word**|=(% style="width: 257px;" %)**Device type**|=(% style="width: 226px;" %)Address NO.|=(% style="width: 349px;" %)Range|=(% style="width: 342px;" %)Note
678 |=(% colspan="1" rowspan="10" style="width: 252px;" %)Bit
679 |(% style="width:257px" %)I|(% style="width:226px" %)DDDD.o|(% style="width:349px" %)D:0~99999  o:0~7|(% style="width:342px" %)
680 |(% style="width:257px" %)Q|(% style="width:226px" %)DDDD.o|(% style="width:349px" %)D:0~99999  o:0~7|(% style="width:342px" %)
681 |(% style="width:257px" %)M|(% style="width:226px" %)DDDD.o|(% style="width:349px" %)D:0~99999  o:0~7|(% style="width:342px" %)
682 |(% style="width:257px" %)V|(% style="width:226px" %)DDDD.o|(% style="width:349px" %)D:0~99999  o:0~7|(% style="width:342px" %)
683 |(% style="width:257px" %)VWBit|(% style="width:226px" %)DDDD.o|(% style="width:349px" %)D:0~99999  o:0~7|(% style="width:342px" %)
684 |(% style="width:257px" %)SM|(% style="width:226px" %)DDDD.o|(% style="width:349px" %)D:0~65535  o:0~7|(% style="width:342px" %)
685 |(% style="width:257px" %)S|(% style="width:226px" %)DDDD.o|(% style="width:349px" %)D:0~99999  o:0~7|(% style="width:342px" %)
686 |(% style="width:257px" %)T|(% style="width:226px" %)DDDD|(% style="width:349px" %)0~99999 |(% style="width:342px" %)
687 |(% style="width:257px" %)C|(% style="width:226px" %)DDDD|(% style="width:349px" %)0~99999 |(% style="width:342px" %)
688 |(% style="width:257px" %)Lamp|(% style="width:226px" %)0|(% style="width:349px" %)0|(% style="width:342px" %)
689 |=(% colspan="1" rowspan="9" style="width: 252px;" %)Word
690 |(% style="width:257px" %)IW|(% style="width:226px" %)DDDD|(% style="width:349px" %)0~99999|(% style="width:342px" %)
691 |(% style="width:257px" %)QW|(% style="width:226px" %)DDDD|(% style="width:349px" %)0~99999|(% style="width:342px" %)
692 |(% style="width:257px" %)AIW|(% style="width:226px" %)DDDD|(% style="width:349px" %)0~99999|(% style="width:342px" %)
693 |(% style="width:257px" %)AQW|(% style="width:226px" %)DDDD|(% style="width:349px" %)0~99999|(% style="width:342px" %)
694 |(% style="width:257px" %)VW|(% style="width:226px" %)DDDD|(% style="width:349px" %)0~99998|(% style="width:342px" %)
695 |(% style="width:257px" %)MW|(% style="width:226px" %)DDDD|(% style="width:349px" %)0 ~~ 30|(% style="width:342px" %)
696 |(% style="width:257px" %)TW|(% style="width:226px" %)DDDD|(% style="width:349px" %)0~99999|(% style="width:342px" %)
697 |(% style="width:257px" %)CW|(% style="width:226px" %)DDDD|(% style="width:349px" %)0~99999|(% style="width:342px" %)
698 |(% style="width:257px" %)SW|(% style="width:226px" %)DDDD|(% style="width:349px" %)0~99999|(% style="width:342px" %)
699 |=(% colspan="1" rowspan="2" style="width: 252px;" %)Double word
700 |(% style="width:257px" %)MD|(% style="width:226px" %)DDDD|(% style="width:349px" %)0-28|(% style="width:342px" %)
701 |(% style="width:257px" %)VD|(% style="width:226px" %)DDDD|(% style="width:349px" %)0 ~~ 99998|(% style="width:342px" %)
702
703 **Viewing/Configuring Ethernet Parameters**
704
705 1.[Tools]~-~-[Ethernet Wizard]
706
707 (% style="text-align:center" %)
708 [[image:图片1.png]]
709
710 2.Choose the position of module 243 ~-~-[Next]
711
712 (% class="box infomessage" %)
713 (((
714 **✎**Note: Module position refers to the position of module 243 on the plc, please adjust according to the actual situation
715 )))
716
717
718 (% style="text-align:center" %)
719 [[image:图片2.png]]
720
721 3.Choose the module type,Next
722
723 (% style="text-align:center" %)
724 [[image:图片3.png]]
725
726 4.Set IP address as 192.168.1.218 ,and Subnet mask as 255.255.255.0,Next
727
728 (% style="text-align:center" %)
729 [[image:图片4.png]]
730
731 5.[QB]1~-~-[Number of connections to configure for this module]3~-~-[Next]
732
733 (% style="text-align:center" %)
734 [[image:图片5.png]]
735
736 6.Click [This is a Server Connection] and Click [Accept all connection requests],[OK]
737
738 (% style="text-align:center" %)
739 [[image:图片6.png]]
740
741 7.Click [Yes,generate CRC protection for  this configuration in the data book],set the Keep Alive Interval as 30 sec,[Next]
742
743 (% style="text-align:center" %)
744 [[image:图片7.png]]
745
746 8.Choose the Suggest Address,Next
747
748 (% style="text-align:center" %)
749 [[image:图片8.png]]
750
751 9.[ETH Configuration for 0]~-~-[Finish]
752
753 (% style="text-align:center" %)
754 [[image:图片9.png]]
755
756 **Test CP 243-1**
757
758 1.[Communications]→[PC/PPI cable]→[TCPIP.1]→[OK]
759
760 (% style="text-align:center" %)
761 [[image:图片10.png]]
762
763
764 2.[Remote]192.168.1.218 then [Double-Click to Refresh]and choose[CPU 226 CN REL 02.01 192.168.1.218],click[OK]
765
766 (% style="text-align:center" %)
767 [[image:图片11.png]]