From version 31.1
edited by Devin Chen
on 2023/09/12 17:45
on 2023/09/12 17:45
Change comment:
There is no comment for this version
To version 33.1
edited by Devin Chen
on 2023/09/15 15:47
on 2023/09/15 15:47
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,18 +19,24 @@ 19 19 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 20 20 |(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 21 21 |Q|Q|Q ddddd.o|0.0~~99999.7| 22 -|V|VWbit|VWbit ddddd.o|0.0~~99999.7| 23 -|V|V|V ddddd.o|0.0~~99999.7| 22 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|HMI register:VWbit 23 +|V|V|V ddddd.o|0.0~~99999.7|HMI register:V 24 24 |M|M|M ddddd.o|0.0~~99999.7| 25 25 |SM|SM|ddddd.o|0.0~~99999.7| 26 26 |S|S|ddddd.o|0.0~~99999.7|Read only 27 27 |T|T|ddddd|0~~99999|Timer state, read only 28 28 |C|C|ddddd|0~~99999|Counter state, read only 29 -|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999| 30 -|Q|QW|QW ddddd|0~~99999| 31 -|AI|AIW|AIW ddddd|0~~99999| 32 -|AQ|VB|VB ddddd|0~~99999| 33 -|V|VW|VW ddddd|0~~99998|((( 29 +|(% colspan="1" rowspan="18" %)Word|(% colspan="1" rowspan="2" %)I|IW|IW ddddd|0~~99999|HMI register:IW 30 +|IB|IB ddddd|0~~99999|HMI register:IB 31 +|(% colspan="1" rowspan="2" %)Q|QW|QW ddddd|0~~99999|HMI register:QW 32 +|QB|QB ddddd|0~~99999|HMI register:QB 33 +|(% colspan="1" rowspan="2" %)AI|AIW|AIW ddddd|0~~99999|HMI register:AIW 34 +|AIB|AIB ddddd|0~~99999|HMI register:AIB 35 +|(% colspan="1" rowspan="2" %)AQ|AQW|AQW ddddd|0~~99999|HMI register:AQW 36 +|AQB|AQB ddddd|0~~99999|HMI register:AQB 37 +|(% colspan="1" rowspan="3" %)V|VW|VW ddddd|0~~99998|((( 38 +HMI register:VW 39 + 34 34 VW0=VB (0~~1) 35 35 36 36 VW2=VB (2~~3) ... ... @@ -37,7 +37,9 @@ 37 37 38 38 Address value is a multiple of 2 39 39 ))) 40 -|V|VD|VD ddddd|0~~99998|((( 46 +|VD|VD ddddd|0~~99996|((( 47 +HMI register:VD 48 + 41 41 VD0=VB (0~~3) 42 42 43 43 VD2=VB (4~~7) ... ... @@ -44,8 +44,10 @@ 44 44 45 45 Address value is a multiple of 4 46 46 ))) 47 -|M|MB|MB ddddd|0~~99999| 48 -|M|MW|MW ddddd|0~~99999|((( 55 +|VB|VB ddddd|0~~99998|HMI register:VB 56 +|(% colspan="1" rowspan="3" %)M|MW|MW ddddd|0~~30|((( 57 +HMI register:MW 58 + 49 49 MW0=MB(0~~1) 50 50 51 51 MW2=MB(2~~3) ... ... @@ -52,7 +52,10 @@ 52 52 53 53 Address value is a multiple of 2 54 54 ))) 55 -|M|MD|MD ddddd|0~~99999|((( 65 +|MD|MD ddddd|0~~99999|((( 66 +((( 67 +HMI register:MD 68 + 56 56 MD0=MB(0~~3) 57 57 58 58 MD4=MB(4~~7) ... ... @@ -59,10 +59,25 @@ 59 59 60 60 Address value is a multiple of 4 61 61 ))) 62 -|T|TW|TW ddddd|0~~99999|Value of timer 63 -|C|CW|CW ddddd|0~~99999|Value of counter 64 -|W|SW|SW ddddd|0~~99999| 65 65 76 +((( 77 + 78 +))) 79 +))) 80 +|MB|MD dd|0~~31|HMI register:MB 81 +|T|TW|TW ddddd|0~~99999|((( 82 +HMI register:MW 83 + 84 +Value of timer 85 +))) 86 +|C|CW|CW ddddd|0~~99999|((( 87 +HMI register:CW 88 + 89 +Value of counter 90 +))) 91 +|(% colspan="1" rowspan="2" %)S|SW|SW ddddd|0~~99999|HMI register:SW 92 +|SB|SB ddddd|0~~99999|HMI register:SB 93 + 66 66 **Communication Settings** 67 67 68 68 Set PLC IP in [Device IP] settings; ... ... @@ -551,7 +551,7 @@ 551 551 552 552 {{id name="Iimage-20221010102051-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_77dc63b5c3645636.png||alt="image-20221010102051-1.png" height="239" width="395"]] 553 553 554 -== **S7-200 Serial ** == 582 +== **S7-200 Smart Serial ** == 555 555 556 556 Supported Series: Siemens S7-200 SMART Series. 557 557