From version 34.1
edited by Devin Chen
on 2023/09/15 15:47
on 2023/09/15 15:47
Change comment:
There is no comment for this version
To version 32.1
edited by Devin Chen
on 2023/09/12 18:42
on 2023/09/12 18:42
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,27 +16,21 @@ 16 16 17 17 **Address List** 18 18 19 -|**Type**|**Device register**|**Format**|**Range**|**Note** 20 -|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| 21 -|Q|Q ddddd.o|0.0~~99999.7| 22 -|V|VWbit ddddd.o|0.0~~99999.7|HMI register:VWbit 23 -|V|V ddddd.o|0.0~~99999.7|HMI register:V 24 -|M|M ddddd.o|0.0~~99999.7| 25 -|SM|ddddd.o|0.0~~99999.7| 26 -|S|ddddd.o|0.0~~99999.7|Read only 27 -|T|ddddd|0~~99999|Timer state, read only 28 -|C|ddddd|0~~99999|Counter state, read only 29 -|(% colspan="1" rowspan="18" %)Word|(% colspan="1" rowspan="2" %)I|IW ddddd|0~~99999|HMI register:IW 30 -|IB ddddd|0~~99999|HMI register:IB 31 -|(% colspan="1" rowspan="2" %)Q|QW ddddd|0~~99999|HMI register:QW 32 -|QB ddddd|0~~99999|HMI register:QB 33 -|(% colspan="1" rowspan="2" %)AI|AIW ddddd|0~~99999|HMI register:AIW 34 -|AIB ddddd|0~~99999|HMI register:AIB 35 -|(% colspan="1" rowspan="2" %)AQ|AQW ddddd|0~~99999|HMI register:AQW 36 -|AQB ddddd|0~~99999|HMI register:AQB 37 -|(% colspan="1" rowspan="3" %)V|VW ddddd|0~~99998|((( 38 -HMI register:VW 39 - 19 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 20 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 21 +|Q|Q|Q ddddd.o|0.0~~99999.7| 22 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7| 23 +|V|V|V ddddd.o|0.0~~99999.7| 24 +|M|M|M ddddd.o|0.0~~99999.7| 25 +|SM|SM|ddddd.o|0.0~~99999.7| 26 +|S|S|ddddd.o|0.0~~99999.7|Read only 27 +|T|T|ddddd|0~~99999|Timer state, read only 28 +|C|C|ddddd|0~~99999|Counter state, read only 29 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999| 30 +|Q|QW|QW ddddd|0~~99999| 31 +|AI|AIW|AIW ddddd|0~~99999| 32 +|AQ|VB|VB ddddd|0~~99999| 33 +|V|VW|VW ddddd|0~~99998|((( 40 40 VW0=VB (0~~1) 41 41 42 42 VW2=VB (2~~3) ... ... @@ -43,9 +43,7 @@ 43 43 44 44 Address value is a multiple of 2 45 45 ))) 46 -|VD ddddd|0~~99996|((( 47 -HMI register:VD 48 - 40 +|V|VD|VD ddddd|0~~99998|((( 49 49 VD0=VB (0~~3) 50 50 51 51 VD2=VB (4~~7) ... ... @@ -52,10 +52,8 @@ 52 52 53 53 Address value is a multiple of 4 54 54 ))) 55 -|VB ddddd|0~~99998|HMI register:VB 56 -|(% colspan="1" rowspan="3" %)M|MW ddddd|0~~30|((( 57 -HMI register:MW 58 - 47 +|M|MB|MB ddddd|0~~99999| 48 +|M|MW|MW ddddd|0~~99999|((( 59 59 MW0=MB(0~~1) 60 60 61 61 MW2=MB(2~~3) ... ... @@ -62,10 +62,7 @@ 62 62 63 63 Address value is a multiple of 2 64 64 ))) 65 -|MD ddddd|0~~99999|((( 66 -((( 67 -HMI register:MD 68 - 55 +|M|MD|MD ddddd|0~~99999|((( 69 69 MD0=MB(0~~3) 70 70 71 71 MD4=MB(4~~7) ... ... @@ -72,25 +72,10 @@ 72 72 73 73 Address value is a multiple of 4 74 74 ))) 62 +|T|TW|TW ddddd|0~~99999|Value of timer 63 +|C|CW|CW ddddd|0~~99999|Value of counter 64 +|W|SW|SW ddddd|0~~99999| 75 75 76 -((( 77 - 78 -))) 79 -))) 80 -|MD dd|0~~31|HMI register:MB 81 -|T|TW ddddd|0~~99999|((( 82 -HMI register:MW 83 - 84 -Value of timer 85 -))) 86 -|C|CW ddddd|0~~99999|((( 87 -HMI register:CW 88 - 89 -Value of counter 90 -))) 91 -|(% colspan="1" rowspan="2" %)S|SW ddddd|0~~99999|HMI register:SW 92 -|SB ddddd|0~~99999|HMI register:SB 93 - 94 94 **Communication Settings** 95 95 96 96 Set PLC IP in [Device IP] settings;