19 -|**Type**|**Device register**|**Format**|**Range**|**Note**
20 -|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7|
21 -|Q|Q ddddd.o|0.0~~99999.7|
22 -|V|VWbit ddddd.o|0.0~~99999.7|HMI register:VWbit
23 -|V|V ddddd.o|0.0~~99999.7|HMI register:V
24 -|M|M ddddd.o|0.0~~99999.7|
25 -|SM|ddddd.o|0.0~~99999.7|
26 -|S|ddddd.o|0.0~~99999.7|Read only
27 -|T|ddddd|0~~99999|Timer state, read only
28 -|C|ddddd|0~~99999|Counter state, read only
29 -|(% colspan="1" rowspan="18" %)Word|(% colspan="1" rowspan="2" %)I|IW ddddd|0~~99999|HMI register:IW
30 -|IB ddddd|0~~99999|HMI register:IB
31 -|(% colspan="1" rowspan="2" %)Q|QW ddddd|0~~99999|HMI register:QW
32 -|QB ddddd|0~~99999|HMI register:QB
33 -|(% colspan="1" rowspan="2" %)AI|AIW ddddd|0~~99999|HMI register:AIW
34 -|AIB ddddd|0~~99999|HMI register:AIB
35 -|(% colspan="1" rowspan="2" %)AQ|AQW ddddd|0~~99999|HMI register:AQW
36 -|AQB ddddd|0~~99999|HMI register:AQB
37 -|(% colspan="1" rowspan="3" %)V|VW ddddd|0~~99998|(((
38 -HMI register:VW
39 -
19 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
20 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
21 +|Q|Q|Q ddddd.o|0.0~~99999.7|
22 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
23 +|V|V|V ddddd.o|0.0~~99999.7|
24 +|M|M|M ddddd.o|0.0~~99999.7|
25 +|SM|SM|ddddd.o|0.0~~99999.7|
26 +|S|S|ddddd.o|0.0~~99999.7|Read only
27 +|T|T|ddddd|0~~99999|Timer state, read only
28 +|C|C|ddddd|0~~99999|Counter state, read only
29 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
30 +|Q|QW|QW ddddd|0~~99999|
31 +|AI|AIW|AIW ddddd|0~~99999|
32 +|AQ|VB|VB ddddd|0~~99999|
33 +|V|VW|VW ddddd|0~~99998|(((
40 40  VW0=VB (0~~1)
41 41  
42 42  VW2=VB (2~~3)
... ... @@ -43,9 +43,7 @@
43 43  
44 44  Address value is a multiple of 2
45 45  )))
46 -|VD ddddd|0~~99996|(((
47 -HMI register:VD
48 -
40 +|V|VD|VD ddddd|0~~99998|(((
49 49  VD0=VB (0~~3)
50 50  
51 51  VD2=VB (4~~7)
... ... @@ -52,10 +52,8 @@
52 52  
53 53  Address value is a multiple of 4
54 54  )))
55 -|VB ddddd|0~~99998|HMI register:VB
56 -|(% colspan="1" rowspan="3" %)M|MW ddddd|0~~30|(((
57 -HMI register:MW
58 -
47 +|M|MB|MB ddddd|0~~99999|
48 +|M|MW|MW ddddd|0~~99999|(((
59 59  MW0=MB(0~~1)
60 60  
61 61  MW2=MB(2~~3)
... ... @@ -62,10 +62,7 @@
62 62  
63 63  Address value is a multiple of 2
64 64  )))
65 -|MD ddddd|0~~99999|(((
66 -(((
67 -HMI register:MD
68 -
55 +|M|MD|MD ddddd|0~~99999|(((
69 69  MD0=MB(0~~3)
70 70  
71 71  MD4=MB(4~~7)
... ... @@ -72,25 +72,10 @@
72 72  
73 73  Address value is a multiple of 4
74 74  )))
62 +|T|TW|TW ddddd|0~~99999|Value of timer
63 +|C|CW|CW ddddd|0~~99999|Value of counter
64 +|W|SW|SW ddddd|0~~99999|
75 75  
76 -(((
77 -
78 -)))
79 -)))
80 -|MD dd|0~~31|HMI register:MB
81 -|T|TW ddddd|0~~99999|(((
82 -HMI register:MW
83 -
84 -Value of timer
85 -)))
86 -|C|CW ddddd|0~~99999|(((
87 -HMI register:CW
88 -
89 -Value of counter
90 -)))
91 -|(% colspan="1" rowspan="2" %)S|SW ddddd|0~~99999|HMI register:SW
92 -|SB ddddd|0~~99999|HMI register:SB
93 -
94 94  **Communication Settings**