... ... @@ -1,1 +1,1 @@
1 -XWiki.joe
1 +XWiki.2454238480
Content
... ... @@ -771,48 +771,50 @@
771 771  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/PLC%20Protocol/Siemens/WebHome/xwiki_PIStudio_12.PLC%2Bprotocols_WebHome_ac8ece9a26719fda.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
772 772  
773 773  
774 -== **Siemens Ethernet FreeTag (S7 Series)** ==
774 +== **Siemens S7-1200/1500 Ethernet Free Tag** ==
775 775  
776 +(% class="box infomessage" %)
777 +(((
778 +Note: Waiting official release
779 +)))
776 776  
777 777  **HMI Setting**
778 778  
779 779  |**Items**|**Settings**|**Note**
780 -|Protocol|Siemens Ethernet FreeTag (S7 Series)|
784 +|Protocol|Siemens S7-1200/1500 Ethernet FreeTag |
781 781  |Connection|Ethernet|
782 782  |Port No.|102|
783 783  |PLC station No.|1|
784 784  
785 -**Address List**
786 -
787 787  **Support Variable Type**
788 788  
789 -|=Data Type|=PIStudio Data Format|=Range
790 -|=BOOL|Bit|0~~1
791 -|=BYTE|16-bit Unsigned/Binary/BCD/Hex|0~~255
792 -|=WORD|16-bit Unsigned/Binary/BCD/Hex|0~~65535
793 -|=DWORD|32-bit Unsigned/Binary/BCD/Hex |0~~4294967295
794 -|=SINT|16-bit Signed/Binary/BCD/Hex|-128~~127
795 -|=USINT|16-bit Unsigned/Binary/BCD/Hex|0~~255
796 -|=INT|16-bit Signed/Binary/BCD/Hex|-32768~~32767
797 -|=UINT|16-bit Unsigned/Binary/BCD/Hex|0~~65535
798 -|=DINT|32-bit Signed/Binary/BCD/Hex|-2147483648~~2147483647
799 -|=UDINT|32-bit Unsigned/Binary/BCD/Hex|0~~4294967295
800 -|=STRING| |
801 -|=Real|32-bit Float|
802 -|=Struct|Bool/Byte/SINT/USINT/WORD/INT/UINT/DWord/DINT/Real/UDINT/String|1.00E-44~~3.40E+38
803 -|=Array|Bool/Byte/SINT/USINT/WORD/INT/UINT/DWord/Dint/Real/DINT/String|
791 +|=Data Type|=PIStudio Data Format
792 +|=BOOL|Bit
793 +|=BYTE|16-bit Unsigned/Binary/BCD/Hex
794 +|=WORD|16-bit Unsigned/Binary/BCD/Hex
795 +|=DWORD|32-bit Unsigned/Binary/BCD/Hex
796 +|=SINT|16-bit Signed/Binary/BCD/Hex
797 +|=USINT|16-bit Unsigned/Binary/BCD/Hex
798 +|=INT|16-bit Signed/Binary/BCD/Hex
799 +|=UINT|16-bit Unsigned/Binary/BCD/Hex
800 +|=DINT|32-bit Signed/Binary/BCD/Hex
801 +|=UDINT|32-bit Unsigned/Binary/BCD/Hex
802 +|=STRING|Max:256
803 +|=Real|32-bit Float
804 +|=Struct|Bool/Byte/SINT/USINT/WORD/INT/UINT/DWord/DINT/Real/UDINT/String
805 +|=Array|Bool/Byte/SINT/USINT/WORD/INT/UINT/DWord/DINT/Real/DINT/String
804 804  
805 805  **Communication Settings**
806 806  
807 -Communication → choose "Siemens Ethernet Free Tag (S7 Series) → OK
809 +Communication → choose "Siemens S7-1200/1500 Ethernet FreeTag" → OK
808 808  
809 809  (% style="text-align:center" %)
810 -[[image:XeIzfQErPZ.png]]
812 +[[image:QiUfoquheO.png]]
811 811  
812 812  Setting→ PLC IP Address → OK
813 813  
814 814  (% style="text-align:center" %)
815 -[[image:U95dFxZlOw.png]]
817 +[[image:p0oBclWpCu.png]]
816 816  
817 817  **PLC Setting**
818 818  
QiUfoquheO.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +124.3 KB
Content