... ... @@ -771,50 +771,48 @@
771 771  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/PLC%20Protocol/Siemens/WebHome/xwiki_PIStudio_12.PLC%2Bprotocols_WebHome_ac8ece9a26719fda.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
772 772  
773 773  
774 -== **Siemens S7-1200/1500 Ethernet Free Tag** ==
774 +== Siemens Ethernet FreeTag (S7 Series) ==
775 775  
776 -(% class="box infomessage" %)
777 -(((
778 -Note: Waiting official release
779 -)))
780 780  
781 781  **HMI Setting**
782 782  
783 783  |**Items**|**Settings**|**Note**
784 -|Protocol|Siemens S7-1200/1500 Ethernet FreeTag |
780 +|Protocol|Siemens Ethernet FreeTag (S7 Series)|
785 785  |Connection|Ethernet|
786 786  |Port No.|102|
787 787  |PLC station No.|1|
788 788  
785 +**Address List**
786 +
789 789  **Support Variable Type**
790 790  
791 -|=Data Type|=PIStudio Data Format
792 -|=BOOL|Bit
793 -|=BYTE|16-bit Unsigned/Binary/BCD/Hex
794 -|=WORD|16-bit Unsigned/Binary/BCD/Hex
795 -|=DWORD|32-bit Unsigned/Binary/BCD/Hex
796 -|=SINT|16-bit Signed/Binary/BCD/Hex
797 -|=USINT|16-bit Unsigned/Binary/BCD/Hex
798 -|=INT|16-bit Signed/Binary/BCD/Hex
799 -|=UINT|16-bit Unsigned/Binary/BCD/Hex
800 -|=DINT|32-bit Signed/Binary/BCD/Hex
801 -|=UDINT|32-bit Unsigned/Binary/BCD/Hex
802 -|=STRING|Max:256
803 -|=Real|32-bit Float
804 -|=Struct|Bool/Byte/SINT/USINT/WORD/INT/UINT/DWord/DINT/Real/UDINT/String
805 -|=Array|Bool/Byte/SINT/USINT/WORD/INT/UINT/DWord/DINT/Real/DINT/String
789 +|=Data Type|=PIStudio Data Format|=Range
790 +|=BOOL|Bit|0~~1
791 +|=BYTE|16-bit Unsigned/Binary/BCD/Hex|0~~255
792 +|=WORD|16-bit Unsigned/Binary/BCD/Hex|0~~65535
793 +|=DWORD|32-bit Unsigned/Binary/BCD/Hex |0~~4294967295
794 +|=SINT|16-bit Signed/Binary/BCD/Hex|-128~~127
795 +|=USINT|16-bit Unsigned/Binary/BCD/Hex|0~~255
796 +|=INT|16-bit Signed/Binary/BCD/Hex|-32768~~32767
797 +|=UINT|16-bit Unsigned/Binary/BCD/Hex|0~~65535
798 +|=DINT|32-bit Signed/Binary/BCD/Hex|-2147483648~~2147483647
799 +|=UDINT|32-bit Unsigned/Binary/BCD/Hex|0~~4294967295
800 +|=STRING| |
801 +|=Real|32-bit Float|
802 +|=Struct|Bool/Byte/SINT/USINT/WORD/INT/UINT/DWord/DINT/Real/UDINT/String|1.00E-44~~3.40E+38
803 +|=Array|Bool/Byte/SINT/USINT/WORD/INT/UINT/DWord/Dint/Real/DINT/String|
806 806  
807 807  **Communication Settings**
808 808  
809 -Communication → choose "Siemens S7-1200/1500 Ethernet FreeTag" → OK
807 +Communication → choose "Siemens Ethernet Free Tag (S7 Series) → OK
810 810  
811 811  (% style="text-align:center" %)
812 -[[image:QiUfoquheO.png]]
810 +[[image:XeIzfQErPZ.png]]
813 813  
814 814  Setting→ PLC IP Address → OK
815 815  
816 816  (% style="text-align:center" %)
817 -[[image:p0oBclWpCu.png]]
815 +[[image:U95dFxZlOw.png]]
818 818  
819 819  **PLC Setting**
820 820  
QiUfoquheO.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.joe
Size
... ... @@ -1,1 +1,0 @@
1 -124.3 KB
Content
p0oBclWpCu.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.joe
Size
... ... @@ -1,1 +1,0 @@
1 -100.6 KB
Content