Changes for page Siemens

Last modified by Joe on 2026/04/01 15:32

From version 6.1
edited by Joe
on 2026/04/01 15:32
Change comment: There is no comment for this version
To version 3.1
edited by Joe
on 2025/12/17 10:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -235,7 +235,7 @@
235 235  
236 236  o: digit address
237 237  )))
238 -|(% colspan="1" rowspan="9" %)Word|M|MB|MB d|d:0-99999|
238 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
239 239  |M|MW|MW d|d:0-99999|(((
240 240  MW0=MB(0~~1)
241 241  
... ... @@ -283,20 +283,7 @@
283 283  
284 284  Address value is a multiple of 4
285 285  )))
286 -|DB0.DB-DB99.DB|DBxDBS|DBxDBSnndddd|(((
287 -nn:0-9999
288 288  
289 -dddd:0-9999
290 -)))|(((
291 -nn:DB No.
292 -
293 -dddd:address value
294 -
295 -Address value is a multiple of 2
296 -
297 -(The data type is for String)
298 -)))
299 -
300 300  **Communication Settings**
301 301  
302 302  Enable HMI Ethernet in [Project Settings];
... ... @@ -331,7 +331,7 @@
331 331  **Such as:**
332 332  
333 333  * DBxDBB20000 = DB2.DBB0
334 -* DBxDBW20002 = DB2.DBW2
321 +* DBxDBW20004 = DB2.DBW4
335 335  
336 336  {{id name="I12.PLCProtocol_html_87ceaea84d552e62.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png||alt="12.PLC Protocol_html_87ceaea84d552e62.png" height="245" width="537"]]
337 337  
... ... @@ -568,11 +568,6 @@
568 568  * VD address should be multiple of 4, because it occupies two VW addresses, such as VD0, VD4, VD8...
569 569  * Written value of RTC cannot exceed 255.
570 570  
571 -(% class="box infomessage" %)
572 -(((
573 -Note: HSW10118 and HSW10119 are supported in HMI V1.0 system. HSW1200 and HSW1201 are supported in HMI V2.0 system.
574 -)))
575 -
576 576  **Cable Wiring**
577 577  
578 578  {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-6"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
... ... @@ -657,18 +657,18 @@
657 657  (% style="text-align:center" %)
658 658  [[image:2.3.2.png]]
659 659  
660 -**PLC Settings**
642 +**PLC Settings(STEP 7-MicroWIN SMART)**
661 661  
662 -**Select "Set PG/PC Interface" in Communication of the View list and Set PG/PC Interface.**
644 +Open STEP 7-MicroWIN SMART, create a new PLC project or open the project that has been created.
645 +Create new project:Double click[CPU SR20]→[System Block]→[Module] CPU SR20(AC/DC/Relay)→[OK].
663 663  
664 -**Select PC/PPI cable PPI.1 and set communication parameters.**
665 -
666 666  (% style="text-align:center" %)
667 -[[image:11.png]]
648 +[[image:1.2.png]]
668 668  
650 +PLC Default Parameters: Double click[CPU SR20]→[System Block]→[RS485 Port]→[Address]2,[Baud Rate]9.6Kbps→[OK]
669 669  
670 670  (% style="text-align:center" %)
671 -[[image:12.png]]
653 +[[image:1.3.png]]
672 672  
673 673  **Cable Wiring**
674 674  