欢迎图片

Why can't the motor rotate normally?

Version 3.1 by Jim on 2023/11/23 17:12

QuestionReasonSolution
Motor doesn't rotateParameter setting error.

(1) Check whether the control mode P0-01 is correct.

(2) Check whether servo are in run status, if not, check P06-02 to P06-04.

(3) Check whether command source selection is correct.

No input command.

(1) Check whether PLC send pulses normally and whether servo receive pulses.

(2) Check whether analog input is in normally range.

Mechanically blocked or not connected

(1) Check whether the load is connected correctly.

(2) Check whether load and mechanical stuck.

(3) Check whether brake device is release.

Motor only rotate in one directionControl command didn't change direction

Please check whether control command changes the direction.

Direction pin burnedIf JOG function works normally when forward rotate and reverse rotate, direction pin burned, please contact technical engineer.